021-52868538
THE RULES OF THE WORLD, THE INNOVATION OF THE WORLD RADIUS.
RGTF series gas turbine flowmeter is a precision metrological instrument used for gas flow measurement. It is elaborately designed and developed by our company with advanced technology, which is characterized in small pressure loss, high accuracy, low starting flow, well vibration and pulsating flow proof performance, and wide range ratio etc.
Considering gas compressibility and close relationship between volume and temperature and pressure of medium, this series flowmeter has added temperature and pressure sensors for tracing change of temperature and pressure of medium, converting the operating condition flow to the flow under normal condition and guaranteeing the accuracy of measurement. RGTF series gas turbine flowmeter can be widely applied in fields such as gas measurement and gas adjustment station for boilers used in petroleum, chemical industry, electric power and industry etc., measurement of natural gas in transmission and distribution pipeline networks and of city natural gas etc.
RGTF series gas turbine flowmeter is a precision metrological instrument used for gas flow measurement. It is elaborately designed and developed by our company with advanced technology, which is characterized in small pressure loss, high accuracy, low starting flow, well vibration and pulsating flow proof performance, and wide range ratio etc.
Considering gas compressibility and close relationship between volume and temperature and pressure of medium, this series flowmeter has added temperature and pressure sensors for tracing change of temperature and pressure of medium, converting the operating condition flow to the flow under normal condition and guaranteeing the accuracy of measurement. RGTF series gas turbine flowmeter can be widely applied in fields such as gas measurement and gas adjustment station for boilers used in petroleum, chemical industry, electric power and industry etc., measurement of natural gas in transmission and distribution pipeline networks and of city natural gas etc.
DESIGN & BENEFIT
² Patent rectification technology can maintain the measurement reliability under unfavorable installation condition and relatively significant change of medium speed flow condition.
² Unique dust-proof structure can effectively prevent impurities in the medium from entering into bearing and resulting in rapid wearing and deadlock.
² Minimum
installation requirement, in which the front straight pipe section ≥ 2D can
ensure measurement accuracy of the flowmeter.
² Aluminum alloy turbine is characterized in high strength, corrosion resistant, ageing resistant, long service life, high accuracy and well repeatability.
² Advanced microcomputer technology and mono-chip computers with high performance enable the complete machine to have more powerful function and more excellent performance.
² Advanced Hi-tech double power supply and micro power consumption enables the complete machine of low power consumption and to be either supplied with internal batteries and run for a long time (two lithium batteries can be used for 3 years) or connected to external power to run.
² Large screen back-lighting LCD display can be read clearly and visually in darker environment.
² Infrared remote operator may be matched and parameter setting can be carried out without opening the front cover of flowmeter.
² The flowmeter is provided with pulse signal output and may also output many signals according to user’s need such as 4 to 20 mA standard analog signals and quantization pulse signals of IC card etc.
² Adopt
RS485, RS232C, MODBUS, HART protocols: they can be matched with specific MODEM
and construct automatic meter reading management system through telephone
network, leading to a high automation level.
² Low
voltage alarm of internal battery (≤2.7V) can remain the user to replace the
battery in time.
² The
intelligent flow totalizer can be turned 180° for convenient reading.
² Data
can be saved automatically when there is power failure to prevent data loss.
² Signal
output check function is provided. It can output the standard current signals
of 4, 8, 12, 16 and 20 mA.
² Liquid
crystal display screen of totalizer can withstand high temperature of 80℃.
SPECIFICATION
v Condition
for Use
Ambient
temperature: -30℃ to +60℃
Medium
temperature: -40℃ to +85℃
Relative
humidity: 5% to 95%
Atmospheric
pressure: 70 kPa to
106 kPa
v Nominal
Diameter: DN25 to DN400, Larger size consult us
v Working
Pressure:0.5 to 4MPa, Larger pressure consult us
v Range
ratio: The measurement range can reach to 40:1
v Accuracy:
±1.0%, ±1.5%
v Repeatability:
Superior to 0.2%
v Explosion-proof
Degree: ExdIIBT4, ExiaIIBT4; protection degree: IP65
v Housing
Material : Aluminum alloy, stainless steel (1Cr18Ni9Ti), ductile cast iron
vPower Supply: 3.6 V lithium battery,
2/3-wire 18 to 30VDC
v Output
signals: 4 to 20 mA
v Communication:
MODBUS, HART
For
Accuracy 1.5%
DN (mm)
Model
Flow Range (m3/h)
Max. Pressure Loss
Range Ratio
Starting Flow (m3/h)
25
RGTF-025
2.5 to 25
0.7kPa
10:1
0.4
40
RGTF-040
6 to 60
0.7kPa
10:1
1.2
50
RGTF-050
8 to 100
0.6kPa
12:1
1.8
80
RGTF-080
17 to 430
0.6kPa
25:1
3.0
100
RGTF-100
25 to 550
0.7kPa
22:1
5.0
150
RGTF-150
37 to 1500
0.8kPa
40:1
10
200
RGTF-200
60 to 2400
0.8kPa
40:1
15
250
RGTF-250
90 to 3600
0.9kPa
40:1
15
300
RGTF-300
150 to 6000
0.9kPa
40:1
15
400
RGTF-400
260 to 8000
0.9kPa
30:1
15
Flow Range